  smartonline 120v 3kva 2.4kw on-line double-conversion ups, extended run, snmp, webcard pre-installed, 3u rack/tower, usb, db9 serial model number: SU3000RTXL3UN description tripp lite smart online ups systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. online, double-conversion uninterruptible power supply (ups) maintains perfectly regulated output power by continuously converting raw ac input to dc, then re-converting output back to ac. fully regulated sine wave ac output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting ups battery reserves. maintains battery-derived ac output during power failures with zero transfer time. extended runtime options available. high 98% efficient operation in optional economy mode saves btu heat output and energy costs. network management interfaces support communications via usb, rs-232, contact-closure and pre-installed snmpwebcard network interface. built-in db9 port offers both enhanced rs-232 data and basic contact closure monitoring ability. hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x. includes poweralert monitoring software and complete cabling. emergency power off (epo) interface. led display reports ups operating mode, line power availability, battery mode operation, inverter operation and output power availability. audible alarm with push-button momentary alarm-cancel. programmable self-test. battery independent restart. fault-tolerant auto-bypass mode. field-replaceable, hot-swappable internal batteries and external battery packs. features tripp lite SU3000RTXL3UN 3000va / 3kva / 2400w on-line, double-conversion 3u rackmount ups selectable 110/120v output (120v factory preset) nema l5-30p input, 4 nema 5-15/20r, 4 5-15r & 1 l5-30r outlets two switched 4-outlet load banks support remote reboot or programmable load shedding options supports 2% output voltage regulation and zero transfer time in double conversion mode economy mode option offers enhanced 98% efficiency operation, reduced power consumption and lower btu emissions highlights 3000va / 3kva / 2400 watt on-line double-conversion 3u rack/tower ups 110/120v +/-2% output at 50/60hz, high 98% efficiency economy mode option expandable runtime, hot-swap batteries, 26 in. / 66cm installed depth usb, rs232, epo ports and pre-installed snmpwebcard front panel status leds with detailed load and battery metering 2 independently switchable output load banks nema l5-30p input; l5-30r, 5-15/20r & 5-15r outlets applications distributed server rooms network closets small business networks voice over ip (voip) phone systems package includes SU3000RTXL3UN ups with pre-installed snmpwebcard poweralert software and cabling mounting hardware for 4 post rack enclosures instruction manual 1 / 5
14 minutes runtime at 50% load (1200w) and 5 minutes at 100% load (2400w) with internal batteries bp72v15-2u (limit 1), bp72v28rt-3u (multi-pack compatible) and bp72v18-2us (multi-pack compatible) external battery packs available (some configurations require tripp lite's external battery configuration software) led display reports ups operating mode, line power availability, battery mode operation, inverter status and output power availability audible alarm with push-button momentary alarm-cancel 4 post installation hardware included, optional 2postrmkithd enables 2 post rack installation single line tel / network surge suppression electronic bypass maintains utility output during a variety of ups fault conditions battery independent restart ensures automatic ups power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement built-in usb, rs-232, contact-closure and pre-installed snmpwebcard network interface hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x included poweralert ups monitoring software specifications output output volt amp capacity (va) 3000 output kva capacity (kva) 3 output watt capacity (watts) 2400 output kw capacity (kw) 2.4 power factor 0.8 crest factor 3:1 nominal output voltage(s) supported 110v; 120v nominal voltage details 120v default frequency compatibility 50 / 60 hz frequency compatibility details output frequency matches input nominal on startup, defaults to 60 hz on cold-start output voltage regulation (line mode) +/- 2% output voltage regulation (economy line mode) +/- 10% output voltage regulation (battery mode) +/- 2% output receptacles (4) 5-15r; (4) 5-15/20r; (1) l5-30r load management receptacles two switchable four-outlet load banks, (bank 1 - four 5-15/20r, bank 2 - four 5-15r outlets) output circuit breakers 15a branch rated (x2) - each breaker protects 4 outlets, l5-30r is unbreakered output ac waveform (ac mode) sine wave output ac waveform (battery mode) pure sine wave 2 / 5
input rated input current (maximum load) 24a nominal input voltage(s) supported 110v ac; 120v ac ups input connection type l5-30p input circuit breakers 40a ups input cord length (ft.) 10 ups input cord length (m) 3 recommended electrical service 30a 120v input phase single-phase battery full load runtime (min.) 5 min. (2400w) half load runtime (min.) 14 min. (1200w) expandable battery runtime supports extended runtime with optional external battery packs external battery pack compatibility bp72v15-2u (limit 1); bp72v28rt-3u (multi-pack compatible); bp72v18-2us (multi-pack compatible) dc system voltage (vdc) 72 battery recharge rate (included batteries) less than 6 hours from 10% to 80% (typical, full load discharge) internal ups replacement battery cartridge rbc96-3u (quantity 1) battery access front panel battery access door battery replacement description hot-swappable, user replaceable batteries voltage regulation voltage regulation description online, double-conversion power conditioning overvoltage correction 2% output voltage regulation during overvoltages to 150 undervoltage correction 2% output voltage regulation during undervoltages to 80 severe undervoltage correction 2% output voltage regulation during undervoltages to 65 (under 70% load only) user interface, alerts & controls switches 2 switches control off/on power status and alarm-cancel/self-test operation alarm cancel operation power-fail alarm can be silenced using alarm-cancel switch audible alarm audible alarm indicates ups startup, power-failure, low-battery, overload, ups fault and remote shutdown conditions led indicators 14 leds indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-led meter displays load and battery charge levels; led panel rotates for viewing in rack/tower formats 3 / 5
surge / noise suppression ups ac suppression joule rating 510 ups ac suppression response time instantaneous ups dataline suppression 1 line tel/dsl (1 in / 1 out); 10/100base t ethernet emi / rfi ac noise suppression yes physical included mounting accessory description includes 4 post rackmount installation accessories installation form factors supported with optional accessories 2 post rackmount (2postrmkithd); tower (2-9ustand) primary form factor rackmount ups power module dimensions (hwd, in.) 5.2 x 17.8 x 26 ups power module dimensions (hwd, cm) 13.3 x 45.1 x 66 rack height (u spaces) 3 ups power module weight (lbs.) 73.8 ups power module weight (kg) 33.5 ups shipping dimensions (hwd / in.) 11.2 x 23 x 31.5 ups shipping dimensions (hwd / cm) 28.6 x 58.4 x 80 shipping weight (lbs.) 112.4 shipping weight (kg) 51 cooling method fan ups housing material steel environmental operating temperature range +32 to +104 degrees fahrenheit / 0 to +40 degrees celsius storage temperature range +5 to +122 degrees fahrenheit / -15 to +50 degrees celsius relative humidity 0 to 95%, non-condensing ac mode btu / hr. (full load) 1112.7 ac economy mode btu / hr. (full load) 520.9 battery mode btu / hr. (full load) 1219.3 ac economy mode efficiency rating (100% load) 98% 4 / 5
communications communications interface contact closure; db9 serial; epo (emergency power off); pre-installed network card; slot for snmp/web interface; usb (hid enabled) network monitoring port description includes pre-installed snmpwebcard interface card. supports detailed monitoring of ups and site power conditions poweralert software included communications cable usb and db9 cabling included watchdog compatibility supports watchdog application, os and hard-reboot restart options for remote applications line / battery transfer transfer time no transfer time (0 ms.) in online, double-conversion mode low voltage transfer to battery power (setpoint) 80v (100% load), 65v ( <70% load) high voltage transfer to battery power (setpoint) 150 special features cold start (startup in battery mode during a power failure) cold-start operation supported high availability ups features automatic inverter bypass; hot swappable batteries green energy-saving features high efficiency economy mode operation; individually controllable load banks; schedulable daily hours of economy mode operation certifications ups certifications tested to ul1778 (usa); tested to csa (canada); tested to nom (mexico); meets fcc part 15 category a (emi) warranty product warranty period (worldwide) 2-year limited warranty connected equipment insurance (u.s., canada & puerto rico) $250,000 ultimate lifetime insurance ? 2015 tripp lite. all rights reserved. all trademarks are the sole property of their respective owners. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. photos may differ slightly from final products. 5 / 5


▲Up To Search▲   

 
Price & Availability of SU3000RTXL3UN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X